WIRING DIAGRAMS
These diagrams represent the four possible
combinations of output wiring. They are in order of
potential. If you find your air gap adjustment to be
at a minimum and wish to try for more power, then try
using the next higher combination. If you find the air
gap is very large, try the next lower one. Note that
there is only a small change in potential between #2
to #3.
CURRENT MEASUREMENT TECHNIQUE
A built-in shunt (precision resistance) is
installed in the junction box, which allows the
current to be measured digitally. This is done with
the supplied DMM (digital multi meter). To measure the
current produced by the generator, set the DMM scale
to "DC milli-volts" or "200 m" at
the nine o'clock position. Plug the leads into their
corresponding color-coded jacks on the shunt in the
junction box. This will give current readings from 0.1
amps to 199.9 amps. Of course, the DMM can be used for
other tasks with your renewable energy system.
|